Call UsCall Us : 08045802536
ST3100M-F Starter 3100M pH  Conductivity Bench

ST3100M-F Starter 3100M pH Conductivity Bench

Product Details:

  • Display Type Backlit LCD
  • Control Type Manual
  • Accuracy 0.5% F.S.; 0.3C; 1 mV; 0.01 pH
  • Features High Quality
  • Type pH/Conductivity Bench Meter
  • Dimension (L*W*H) 175 mm x 78 mm x 220 mm (6.89 x 3.07 x 8.66 in)
  • Power 100 - 240 V
  • Click to View more
X

ST3100M-F Starter 3100M pH Conductivity Bench Price And Quantity

  • 1 Piece
  • 0.01 pH, 1 mV, 0.01 S/cm
  • 30 k NTC
  • 0.95 kg
  • -1999 to 1999 mV
  • -5C to 40C, 85%RH
  • ST310, STCON3
  • 0.1C
  • 0.0 - 199.9 S/cm
  • -5C to 110C
  • 0 to 20 M
  • In-use cover included
  • Automatic
  • -2 to 20

ST3100M-F Starter 3100M pH Conductivity Bench Product Specifications

  • Plastic & Glass
  • pH/Conductivity Bench Meter
  • 100 - 240 V
  • 175 mm x 78 mm x 220 mm (6.89 x 3.07 x 8.66 in)
  • High Quality
  • Laboratory
  • 0.5% F.S.; 0.3C; 1 mV; 0.01 pH
  • Manual
  • Backlit LCD
  • 0.01 pH, 1 mV, 0.01 S/cm
  • 30 k NTC
  • 0.95 kg
  • -1999 to 1999 mV
  • -5C to 40C, 85%RH
  • ST310, STCON3
  • 0.1C
  • 0.0 - 199.9 S/cm
  • -5C to 110C
  • 0 to 20 M
  • In-use cover included
  • Automatic
  • -2 to 20

ST3100M-F Starter 3100M pH Conductivity Bench Trade Information

  • 100 Piece Per Month
  • 7 Days

Product Description

Product details

Measurement Range

-2.00 20.00 pH;0-20 Mcm;-5 C 110 C;00.0 S/cm 199.9 mS/cm;-1999 1999 mV

Accuracy

0.5 % F.S.;0.3 C;1 mV;0.01 pH

Measurement Resolution

0.1 C;0.01 pH;0.01 cm;0.01 S/cm;1 mV

Item Number:

30276083

Specification

Measurement Range

-2.00 20.00 pH;  0-20 Mcm;  -5 C 110 C;  00.0 S/cm 199.9 mS/cm;  -1999 1999 mV

Accuracy

0.5 % F.S.;  0.3 C;  1 mV;  0.01 pH

Measurement Resolution

0.1 C;  0.01 pH;  0.01 cm;  0.01 S/cm;  1 mV

Display

Backlit LCD

Electrode

ST310 (Included);  STCON3 (Included)

Accuracy (mV)

1 mV

Accuracy (Temperature)

0.3 C

Battery Life

Not applicable

Conductivity accuracy ()

0.5 %

Conductivity measuring range

0.0 199.9 S/cm

Dimensions

6.89 in x 3.07 in x 8.66 in (175 mm x 78 mm x 220 mm) (LxHxW)

In-Use Cover

Included

Measurement Range (Temperature)

-5 C ;  110 C

Measurement Range

-1,999 mV ;  1,999 mV

Net Weight

2.09 lb (0.95 kg)

pH accuracy ()

0.01

pH measuring range

-2 ;  20

pH resolution

0.01

Power

100 - 240 V

Resistivity measuring range

0 MOhm ;  20 MOhm

Resistivity resolution

0.01 MOhm

Resolution Cond. (Variable)

0.01 ;  200

Resolution (Voltage)

1 mV

Temperature compensation

Automatic

Temperature resolution

0.1 C

Temperature Sensor

30 K NTC

Working Environment

14F 104F, 85%RH, non-condensing (-5C 40C, 85%RH, non-condensing)




Versatile All-in-One Measurement Solution

The ST3100M-F Starter 3100M Bench Meter seamlessly measures pH, conductivity, resistivity, and voltage, making it suitable for various laboratory and industrial environments. Its wide measurement ranges and high-resolution sensor technology cater to the most demanding analysis needs.


Precision and Usability Combined

With automatic temperature compensation, manual control, and a backlit LCD display, this meter delivers fast, accurate results every time. The included in-use cover ensures components stay safe during operations, and the compact, lightweight design suits any lab bench.


Robust Design for Consistent Results

Built from quality plastic and glass materials, the ST3100M-F bench meter is engineered for durability. Its streamlined dimensions, stable functionality in a range of environmental conditions, and easy maintenance further enhance reliability for daily laboratory use.

FAQ's of ST3100M-F Starter 3100M pH Conductivity Bench:


Q: How do I set up and use the ST3100M-F Starter 3100M Bench Meter?

A: To set up the ST3100M-F, connect the ST310 and STCON3 electrodes, plug in the 30 k NTC temperature sensor, and power the unit with the supplied 100-240 V adapter. Calibration is straightforward using standard solutions before measuring samples for pH, conductivity, resistivity, or voltage. The manual controls and automatic temperature compensation help ensure accurate readings during use.

Q: What are the main benefits of using this pH/conductivity meter in a laboratory?

A: The main benefits include precise multi-parameter measurements (pH, conductivity, resistivity, voltage), wide measurement ranges, fast response times, and automatic temperature compensation. Its compact design, backlit display, and included electrode cover contribute to user convenience and measurement consistency.

Q: When should calibration be performed for optimal accuracy?

A: Calibration should be performed before first use, after any electrode cleaning or replacement, and periodically as specified in the user manual-typically before each critical measurement session to maintain maximum accuracy.

Q: Where can the ST3100M-F be effectively used?

A: This bench meter is ideal for laboratory environments in academic, industrial, or scientific research settings. Its broad working temperature (-5C to 40C) and humidity tolerance (up to 85% RH) allow use in most standard lab conditions.

Q: What is the process for measuring temperature with this device?

A: The 30 k NTC temperature sensor automatically detects sample temperature within a -5C to 110C range, displaying readings in 0.1C resolution. Temperature compensation is applied automatically to improve accuracy of pH and conductivity measurements.

Q: How does automatic temperature compensation benefit my measurements?

A: Automatic temperature compensation ensures that pH and conductivity readings are corrected for temperature variations, providing reliable results that reflect the actual properties of the sample, regardless of ambient temperature changes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail